Valvular & structural heart disease

Intravascular Ultrasound Assessment of Coronary Arteries at High Risk for Obstruction Following Transcatheter Aortic Valve Replacement (TAVR): The ICARO Study

JACC Cardiovasc IntervPublished Prospective observational study

Authors' conclusion

This first multicenter investigation on the IVUS use in the setting of CAO during TAVR suggests that the technique is both feasible and safe.

Study context

Population
Native and valve-in-valve TAVR with ≥2 radiological predefined high-risk characteristics for coronary artery obstruction
Participants
32 participants40 vessels
Exposure
Intravascular ultrasound (IVUS)-guided decision on chimney stenting after TAVR
  • Stentsn = 16
  • Deferredn = 16reference
Outcome
Feasibility and safety of IVUS assessment after TAVR
Methodological detailsmulticentre
  • Multicentre

Main finding

As reported in the abstract

Sudden coronary artery obstruction (CAO) requiring urgent chimney stenting before IVUS
2

Observational data: associations, not effects.

Secondary outcomes

Chimney stenting deferred after IVUS

Chimney deferred
24 of 38 cases (63%; 95% CI: 50%-78.9%)

IVUS features guiding stenting

Minimal cross-sectional area at the ostial-paraostial space and distance of the displaced leaflet from the coronary ostium

Safety

OutcomeDeferredEstimateP value
MACCE · median follow-up 366 days (Q1-Q3: 119-780 days)Stented vs Deferred · did not differ6.2%(95% CI 0%–15.6%)P = 0.958
  • MACCE: Stented 6.2%

Original publication

Intravascular Ultrasound Assessment of Coronary Arteries at High Risk for Obstruction Following TAVR: The ICARO Study. JACC Cardiovasc Interv. Published 12 May 2025. doi:10.1016/j.jcin.2025.03.016

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.