Arrhythmias & electrophysiology

Impact of a universal monitoring system (“third party”) on outcomes of ICD patients: A nationwide study

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

RM was associated with improved survival in ICD recipients. Importantly, we found that use of UMS was associated with additional improvement in clinical outcomes, including survival and hospitalizations.

Study context

Population
ICD patients in the French nationwide health database, 2019
Participants
69,394 patients
Exposure
Remote monitoring (RM) vs no RM; Universal monitoring system (UMS) vs conventional RM
Outcome
Adjusted annual mortality and hospitalizations (all-cause, HF, number, duration)
Follow-up
1 year (2019)
Methodological detailsnationwide
  • Nationwide

Main finding

As reported in the abstract

Mortality
Hazard ratio (95% CI)P value
RMvs no-RM
0.96(0.95–0.97)
P < 0.001
UMSvs Conventional RM
0.74(0.73–0.77)
P < 0.001

Observational data: associations, not effects.

Further findings

OutcomeHR (95% CI)P value
Cumulative duration of all-cause hospitalizationsRMvs no-RMHospitalizations increased in number0.98 (0.98–0.99)P < 0.001
All-cause and HF hospitalizationsUMSvs Conventional RM0.96 (0.95–0.97)P < 0.001
Hospital stay durationUMSvs Conventional RM0.96 (0.95–0.97)P < 0.001

Original publication

Impact of a universal monitoring system (“third party”) on outcomes of ICD patients: A nationwide study. Heart Rhythm. Published 22 November 2024. doi:10.1016/j.hrthm.2024.11.029

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.