Impact of echocardiographic analyses of valvular event timing on myocardial work indices
Authors' conclusion
Myocardial work indices differ depending on the event timing modality used, with visual assessment yielding lower GWI values compared with Doppler-based methods.
Study context
- Population
- Healthy subjects and patients with aortic valve sclerosis, AF or reduced LVEF (50 each); median age 72 years, 50% men50 per subgroup
- Participants
- 200 subjects
- Comparison
- Valvular event timing by spectral Doppler vs colour tissue Doppler imaging (TDI) M-mode vs visual assessment for pressure-strain loop (PSL) myocardial work
- Outcome
- Myocardial work indices, incl. global work index (GWI)
Main finding
As reported in the abstract
GWI
Mean difference
114 mmHg%
P < 0.001
Spectral Doppler vs Visual assessment · ± 93
Mean difference
83 mmHg%
P < 0.001
TDI vs Visual assessment · ± 90
Mean difference
30 mmHg%
P < 0.001
Spectral Doppler vs TDI · ± 53
Key notes
- Valvular event timings and all myocardial work indices differed between all three modalities
Further findings
Global work index (GWI), healthy subgroup
| Outcome | Mean difference (mmHg%) | P value |
|---|---|---|
| Spectral Doppler vs Visual assessment · ± 77 · systematic bias | 160 | P < 0.001 |
| TDI vs Visual assessment · ± 74 | 124 | P < 0.001 |
Original publication
Impact of echocardiographic analyses of valvular event timing on myocardial work indices. Eur Heart J Cardiovasc Imaging. Published 19 August 2022. doi:10. 1093/ ehjci/ jeac171
Composed by AI from the published abstract and checked against it. How Briefs are made →