Aortic & peripheral vascular diseaseCohort study

Low-Dose vs High-Dose Drug-Coated Balloon for Symptomatic Femoropopliteal Artery Disease

JACC Cardiovasc IntervPublished

  • Prospective nonrandomized trial
  • multicentre
  • propensity-score matched

Authors' conclusion

LD-DCBs demonstrate efficacy and safety comparable with HD-DCBs in patients with complex clinical backgrounds

Study context

Population
Patients undergoing endovascular therapy for symptomatic femoropopliteal artery disease (Rutherford classes 2–5)
Participants
581 patients · 163 matched pairs
Exposure
Low-dose DCB vs high-dose DCB
  • LD-DCBn = 370
  • HD-DCBn = 211reference
Outcome
Primary patency of LD-DCB vs HD-DCB, by propensity score matching
Follow-up
1 year

Main finding

1-year primary patency

Hazard ratio

0.93

95% CI 0.55–1.59

P = 0.79

By group

LD-DCB vs HD-DCB
HR 0.93 (95% CI 0.55–1.59); P = 0.79

As reported in the abstract

Observational data: associations, not effects.

Further findings

Interaction of baseline characteristics with 1-year restenosis risk

No baseline characteristic had a significant interaction effect

Safety

OutcomeLD-DCBHD-DCBOR (95% CI)P value
Impaired flow after DCB application · matched population13.6%9.8%1.46 (0.78–2.73)P = 0.24

Original publication

Low-Dose vs High-Dose Drug-Coated Balloon for Symptomatic Femoropopliteal Artery Disease. JACC Cardiovasc Interv. Published 4 October 2023. doi:10.1016/j.jcin.2023.08.022

Summarised from the published abstract; every number is checked against it