Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site

EuropacePublished Prospective cohort study

Authors' conclusion

The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response.

Study context

Population
Consecutive cardiac resynchronization therapy (CRT) patients undergoing electrocardiographic Imaging (ECGI) and chest/heart CT 6–24 months post-implant
Participants
111 patients
Exposure
Distance of left ventricle (LV) pacing site to latest electrically activated site (ECGI) in CRT responders vs non-responders
Outcome
CRT response (LVESV reduction ≥15%)
Follow-up
10 ± 3 months post CRT-implant
Methodological detailsconsecutive patients
  • Consecutive patients

Main finding

As reported in the abstract

Distance from LV pacing site (LVPS) to LEAS (dp)

P < 0.001

Responders
67%
Overall dp
42 ± 23 mm
Longer dp and lack of CRT optimization algorithm use the only independent predictors of non-response (AUC)
0.906
Dp of 47 mm delineated responders and non-responders (AUC)
0.931

Observational data: associations, not effects.

Further findings

Latest electrically activated site (LEAS) location

LEAS outside mid-to-basal lateral segments
35%

Original publication

Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site. Europace. Published 1 March 2023. doi:10.1093/europace/euad041

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.