Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold in Coronary Artery Stenosis: The OPTIMIS Trial

Circ Cardiovasc IntervPublished randomized

Authors' conclusion

Lesion preparation with a scoring balloon before implantation of a Magmaris BRS resulted in a significantly larger minimal lumen area after 6 months due to less negative remodeling compared with lesion preparation with a standard noncompliant balloon.

Study context

Population
Patients with stable angina undergoing implantation of a Magmaris bioresorbable scaffolds (BRS)6-month follow-up with OCT and IVUS available in 74 patients
Participants
82 patients
Comparison
Lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS
Primary endpoint
minimal lumen area
Follow-up
6-month follow-up
Methodological details1:1 ratio
  • 1:1 ratio

Primary result

As reported in the abstract

Scoring balloon

4.7±1.4

mm²

Standard noncompliant balloon

3.9±1.9

mm²

P = 0.04

Further findings

OutcomeScoring balloonStandard noncompliant balloonP value
Post-implantation minimal lumen area, mean scaffold area, mean lumen area · Following Magmaris BRS implantationDid not differ significantly
Minimal lumen area6.4±1.66.3±1.5
Mean scaffold area7.8±1.57.5±1.7
Mean lumen area8.0±1.67.7±2.1
Mean lumen area · 6 monthsDid not differ significantly7.2±1.4 mm²6.8±2.2 mm²P = 0.35
IVUS mean vessel area at lesion site, baseline to follow-up · baseline to 6-month follow-up16.8±2.9 versus 17.0±3.6 mm²17.1±4.4 versus 15.7±4.9 mm²
  • Post-implantation minimal lumen area, mean scaffold area, mean lumen area: minimal lumen area P =0.65
  • Post-implantation minimal lumen area, mean scaffold area, mean lumen area: mean scaffold area P =0.37
  • Post-implantation minimal lumen area, mean scaffold area, mean lumen area: mean lumen area P =0.41
  • IVUS mean vessel area at lesion site, baseline to follow-up: scoring balloon: no difference, P =0.62
  • IVUS mean vessel area at lesion site, baseline to follow-up: standard noncompliant balloon: smaller due to negative remodeling, P <0.001

Original publication

Optimal Predilatation Treatment Before Implantation of a Magmaris Bioresorbable Scaffold in Coronary Artery Stenosis: The OPTIMIS Trial. Circ Cardiovasc Interv. Published 21 January 2025. doi:10.1161/circinterventions.124.014665

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.