Arrhythmias & electrophysiology

Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia

JACC Clin ElectrophysiolPublished Mechanistic study

Authors' conclusion

Peak frequencies at MRAT termination sites are substantially higher than global atrial PFs, supporting the potential of PF mapping as an effective tool for identifying critical isthmuses in MRAT ablation procedures.

Study context

Population
Patients undergoing ablation of macro-re-entrant atrial tachycardia (MRAT) with fully mapped circuits and termination during ablation
Participants
17 patients21 MRATs
Comparison
Peak Frequency (PF) at termination sites vs global atrial PF
Outcome
Peak frequency (PF)
Methodological detailsconsecutive patients
  • Consecutive patients

Main finding

As reported in the abstract

Max PF at termination sites (mean ± SD)
615.2 ± 85.7 Hz
Global PF (mean ± SD); vs termination sites P < 0.01
317.6 ± 45.4 Hz
PF within 5-mm termination diameter (mean ± SD); vs max at termination P < 0.01
499.6 ± 115.4 Hz
PF threshold differentiating isthmus regions from global atrial PF
363 Hz
PF threshold indicating max PF at termination sites
>530 Hz

Further findings

Voltage

Termination sites (mean ± SD)
0.39 ± 0.56
Global average (mean ± SD); P < 0.01
0.73 ± 0.57

Ablation lesions required for termination

Median lesions (Q1-Q3: 1-7)
1
Terminated after initial lesion
48%

Original publication

Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia. JACC Clin Electrophysiol. Published 20 August 2025. doi:10.1016/j.jacep.2025.06.037

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.