Arrhythmias & electrophysiology

Predictive Value of PET-Derived Myocardial Flow Reserve for New-Onset Atrial Fibrillation

Circ Cardiovasc ImagingPublished Multivariable Cox analysis of patients who underwent positron emission tomography MPI

Main finding · New-onset AFResult — go to the resultHazard ratio 0.58 95% CI 0.47–0.72

Authors' conclusion

Impaired positron emission tomography-derived MFR is independently associated with increased risk of new-onset AF and enhances risk prediction beyond clinical factors and LVEF, suggesting a role for coronary microvascular dysfunction in early AF pathogenesis.

Study context

Population
Patients without prior atrial fibrillation (AF) who underwent positron emission tomography MPI
Participants
10,500 patients
Comparison
Association between myocardial flow reserve (MFR) and incident AF, and models with and without MFR
Outcome
New-onset AF
Follow-up
Median 640 days
Methodological details2 centers
  • 2 centers

Main finding

New-onset AF

Hazard ratio

0.58

95% CI 0.47–0.72

P < 0.0001

MFR (per 1 interquartile range increase)
HR 0.58 (95% CI 0.47–0.72); P < 0.0001

Per 1 interquartile range increase, as printed

As reported in the abstract

Patients who developed AF
288 (2.74%)
Incidence of AF with impaired MFR (<2), per 1000 person years
20.5 versus 8.3

Further findings

Stress and rest myocardial blood flow as predictors of AF

Stress and rest myocardial blood flow were not significant predictors

Incremental predictive value of MFR (C-index)

C-index added to clinical variables
0.675-0.726
C-index added to clinical variables, left ventricular ejection fraction (LVEF), and summed stress score
0.758-0.770
C-index added to CHARGE-AF risk score
0.638 to 0.711
  • P <0.001

New-onset AF by EF (subgroup)

Association numerically greater in patients with preserved EF; interaction term not statistically significant

Original publication

Predictive Value of PET-Derived Myocardial Flow Reserve for New-Onset Atrial Fibrillation. Circ Cardiovasc Imaging. Published 13 November 2026. doi:10.1161/circimaging.126.019811

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.