Arrhythmias & electrophysiology

Prognosis and Management of Recurrent Stenosis After Pulmonary Vein Stenting: A Prospective Study

JACC Clin ElectrophysiolPublished Prospective observational study

Main finding · Recurrent ISR (per vein)Result — go to the resultHazard ratio 0.21 95% CI 0.07–0.64

Authors' conclusion

Our modified stent-in-stent implantation approach is superior to BA for treating pulmonary vein ISR, by reducing recurrent restenosis rate and improving exercise endurance.

Study context

Population
Patients with severe pulmonary vein stenosis after radiofrequency ablation for AF, treated with stenting174 stented veins
Participants
107 patients
Exposure
Modified stent-in-stent vs balloon angioplasty for pulmonary vein in-stent restenosis (ISR)
Outcome
Recurrent ISR after reintervention

Main finding

Recurrent ISR (per vein)

Hazard ratio

0.21

95% CI 0.07–0.64

P = 0.02

Events by group

Stent-in-stentvs BA
HR 0.21 (95% CI 0.07–0.64); P = 0.02

As reported in the abstract

Observational data: associations, not effects.

Further findings

Reintervention success rate

ISR after initial stenting (single group)

Veins with ISR (43 of 174; 36 patients)
24.7%

Stent diameter, veins with vs without ISR

Smaller stents in veins developing ISR: 7.8 ± 0.8 mm vs 9.2 ± 0.7 mm
P = 0.008

Exercise endurance and WHO cardiac functional class · 6 and 12 months

Greater exercise endurance with stent-in-stent vs balloon angioplasty (BA) (F = 7.2)
P < 0.05
Better WHO functional class with stent-in-stent vs BA (F = 4.4)
P < 0.05

Original publication

Prognosis and Management of Recurrent Stenosis After Pulmonary Vein Stenting: A Prospective Study. JACC Clin Electrophysiol. Published 27 November 2024. doi:10.1016/j.jacep.2024.09.022

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.