Arrhythmias & electrophysiology

Rate of Change of Initial Intrinsicoid Deflection Predicts Endocardial Versus Epicardial Ventricular Tachycardia

JACC Clin ElectrophysiolPublished Diagnostic accuracy study

Authors' conclusion

This study demonstrates that depolarization rate analysis is a potential technique to predict if a VT is epicardial in nature.

Study context

Population
Patients with VT in nonischemic cardiomyopathy
Participants
26 patients
Comparison
Epicardial vs endocardial VT: initial rate of change of depolarization on signal-averaged 12-lead electrocardiographic (ECG)
Outcome
Rate of change of initial VT depolarization (signal-averaged 12-lead ECG)

Performance

As reported in the abstract

Rate of change of depolarization

Epicardial

6.3

± 3.1 · mV/s

Endocardial

11.4

± 3.7 · mV/s

P < 0.05

Further findings

ROC prediction of epicardial VT origin

AUC range
0.72-0.88
Slower rate of change of depolarization had high sensitivity and specificity for epicardial VT

Original publication

Rate of Change of Initial Intrinsicoid Deflection Predicts Endocardial Versus Epicardial Ventricular Tachycardia. JACC Clin Electrophysiol. Published 1 May 2024. doi:10.1016/j.jacep.2024.02.028

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.