Arrhythmias & electrophysiology
Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry
Authors' conclusion
In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.
Study context
- Population
- Patients with atrial fibrillation (AF) undergoing post-approval pulsed field ablation, March 2021–May 2022
- Participants
- 1,568 patients
- Outcome
- Freedom from clinically documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) ≥30 s on ECG after 3-month blanking (on or off antiarrhythmic drugs)
- Follow-up
- 1 year
Methodological details24 European centres, prospective inclusion in centre registries
- 24 European centres
- Prospective inclusion in centre registries
Main finding
As reported in the abstract
1-year Kaplan-Meier estimate for freedom from atrial arrhythmia
78.1%
95% CI 76.0%–80.0%
Observational data: associations, not effects.
Further findings
Clinical effectiveness by AF type (subgroup) · 1 year
P = 0.001
Pulmonary vein isolation achieved
- Pulmonary vein isolation achieved
- 99.2%
Safety
Acute major adverse events (<7 days postprocedure)
- Acute major adverse events
- 1.9%
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →