Valvular & structural heart disease

Self-Expanding or Balloon-Expandable Transcatheter Aortic-valve Replacement (TAVR) in Patients with a Small Aortic Annulus

N Engl J MedPublished Randomised controlled trial

Authors' conclusion

Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months.

Study context

Population
Patients with symptomatic severe AS and an aortic-valve annulus area of 430 mm² or less
Participants
716 patients
Comparison
Self-expanding supraannular valve vs balloon-expandable valve for TAVR
Primary endpoint
Coprimary: composite of death, disabling stroke or rehospitalization for HF (noninferiority); composite of bioprosthetic-valve dysfunction (superiority)
Follow-up
12 months
Methodological detailsnon-inferiority, 83 sites in 13 countries
  • Non-inferiority
  • 83 sites in 13 countries

Primary result

As reported in the abstract

Self-expanding valve

Death, disabling stroke or HF rehospitalization (Kaplan-Meier)
9.4%
Bioprosthetic-valve dysfunction (Kaplan-Meier)
9.4%

Balloon-expandable valve

Death, disabling stroke or HF rehospitalization (Kaplan-Meier)
10.6%
Bioprosthetic-valve dysfunction (Kaplan-Meier)
41.6%

Death, disabling stroke or HF rehospitalization (Kaplan-Meier)

Self-expanding valve9.4%
Balloon-expandable valve10.6%

Bioprosthetic-valve dysfunction (Kaplan-Meier)

Self-expanding valve9.4%
Balloon-expandable valve41.6%
Self-expanding valve vs Balloon-expandable valveEstimateP value
Death, disabling stroke or HF rehospitalization
difference −1.2 percentage points(90% CI −4.9 to 2.5)
P < 0.001 for noninferiority
Bioprosthetic-valve dysfunction
difference −32.2 percentage points(95% CI −38.7 to −25.6)
P < 0.001 for superiority

Secondary outcomes

Aortic-valve mean gradient · 12 months

P < 0.001

Mean effective orifice area · 12 months

P < 0.001

Hemodynamic structural valve dysfunction · 12 months

P < 0.001

Bioprosthetic-valve dysfunction in women (subgroup) · 12 months

P < 0.001

Moderate or severe prosthesis-patient mismatch · 30 days

P < 0.001

Safety

Major safety end points

Appeared to be similar in the two groups

Original publication

Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus. N Engl J Med. Published 7 April 2024. doi:10.1056/nejmoa2312573