Arrhythmias & electrophysiology

Slowly conducting anatomic isthmuses of tetralogy of Fallot: An opportunity for “prophylactic” ventricular tachycardia ablation

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

Prophylactic SCAI ablation is associated with fewer ICD implantations and a reduction in incident arrhythmic events without ablation-related complications.

Study context

Population
Patients with repaired tetralogy of Fallot undergoing risk stratification electrophysiologic studies
Participants
92 patients
Exposure
Prophylactic SCAI ablation vs historical strategy
  • Prophylacticn = 57
  • Historicaln = 35reference
Outcome
Composite of:
  • Arrhythmic death
  • Cardiac arrest
  • Sustained VT
  • ICD complication
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

GroupValueMedian follow-up
Prophylactic0 events21 months (IQR 8-35 months)
Historical29%125 months (IQR 90-142 months)

Value

Prophylactic0 events
Historical29%

Median follow-up

Prophylactic21 months (IQR 8-35 months)
Historical125 months (IQR 90-142 months)
  • Prophylactic vs Historical: P = 0.017

Observational data: associations, not effects.

Further findings

Inducible VT · Prophylactic: before ablation

Events

OutcomeProphylacticHistorical
ICD implantation111
Slowly conducting anatomic isthmuses (SCAIs) identified or ablated (Prophylactic)
58% · 33 of 57

Safety

No ablation-related complications

Original publication

Slowly conducting anatomic isthmuses of tetralogy of Fallot: An opportunity for “prophylactic” ventricular tachycardia ablation. Heart Rhythm. Published 17 November 2024. doi:10.1016/j.hrthm.2024.10.073

Composed by AI from the published abstract and checked against it. How Briefs are made →