Arrhythmias & electrophysiology

Spatial ventricular gradient is associated with pacing-induced cardiomyopathy

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

Assessment of the SVG both before and immediately after pacemaker implantation can help identify patients at elevated risk of PICM

Study context

Population
Patients with pacemakers implanted 2003–2012 at the Hospital of the University of Pennsylvania
Participants
203 patients
Exposure
Higher vs lower tertiles of mean adjusted spatial ventricular gradient (SVG) azimuth
Outcome
Pacing-induced cardiomyopathy (PICM)
Follow-up
Over
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

PICM

Adjusted hazard ratio

1.95

P = 0.047

SVG azimuth before pacemaker implantation

Adjusted hazard ratio

2.55

P = 0.003

SVG azimuth immediately after pacemaker implantation

Observational data: associations, not effects.

Further findings

Pacing-induced cardiomyopathy (PICM) incidence during follow-up

Developed PICM
44 (22%)

Unadjusted predictors of PICM

Male sex, native QRS duration (without bundle branch block), and native and paced mean adjusted SVG azimuth predicted future PICM in unadjusted Cox regression

Original publication

Spatial ventricular gradient is associated with pacing-induced cardiomyopathy. Heart Rhythm. Published 28 December 2024. doi:10.1016/j.hrthm.2024.12.037

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.