Valvular & structural heart disease

Transcatheter Aortic Valve Replacement for Aortic Regurgitation: A Systematic Review and Meta-Analysis

ESC Heart FailPublished Systematic review and meta-analysis

Authors' conclusion

On-label devices showed significantly better safety and efficacy in terms of the success rate, PPI, greater-than-mild PVL, and 30 day mortality than off-label devices.

Study context

Population
Patients with severe aortic regurgitation undergoing TAVR with new-generation devices
Participants
1,851 patients31 studies
Comparison
On-label vs off-label new-generation TAVR devices
  • On-labeln = 1,067
Outcome
Device success
Follow-up
30 days
Methodological detailsMEDLINE, Embase, Cochrane Library and Scopus searched through April 2023
  • MEDLINE, Embase, Cochrane Library and Scopus searched through April 2023

Pooled result

As reported in the abstract

P < 0.001

Total device success, all new-generation devices (NGDs)
94.5%

Further pooled results

All-cause mortality · 30 days

P = 0.006

All-cause mortality — All NGDs
4.2%

Safety

Permanent pacemaker implantation · 30 days

P < 0.001

Greater-than-mild paravalvular leak · 30 days

P = 0.003

Permanent pacemaker implantation — All NGDs
8.8%
Greater-than-mild paravalvular leak — All NGDs
1.2%

Original publication

Transcatheter Aortic Valve Replacement for Aortic Regurgitation: A Systematic Review and Meta-Analysis. ESC Heart Fail. Published 15 May 2024. doi:10.1002/ehf2.14832

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.