Arrhythmias & electrophysiology

Transseptal puncture for catheter ablation of atrial fibrillation in patients with septal occluder devices

Heart RhythmPublished multicenter, prospective observational study

Authors' conclusion

TSP and PVI are safe and can be safely performed in patients with an ASO. No additional substrate related to the occluder was seen. Although no direct comparison was made, outcomes align with existing literature. Further studies are needed.

Study context

Population
Patients with drug-refractory atrial fibrillation (AF) and atrial septal occluders (ASOs) in situ for atrial septal defects (ASDs) or persistent foramen ovale (PFO) who underwent pulmonary vein isolation (PVI) between 2019 and 2024mean age 61.2 ± 12.1 years, 56% male · ASDs 38 · PFOs 21
Participants
59 patients
Outcome
TSP position in the interatrial septum related to the ASO

Main finding

As reported in the abstract

Inferior-posterior to the ASO

66.1%

Inferior-anterior

23.7%

Superior-posterior puncture (in case of failure of the inferior part)

8.5%

Puncture through the occluder (in case of failure of the inferior part)

1.7%

Observational data: associations, not effects.

Further findings

Ablation time and energy source

Mean ablation time
14.9 ± 8.4 minutes
Radiofrequency
83.0%
Cryoballoon
11.9%
Pulsed field ablation
5.1%

Voltage mapping

No additional substrate related to the occluder

AF recurrence · 12-month follow-up

Patients with AF recurrence
7 patients (11.9%)

Safety

Transient phrenic nerve palsy during cryoballoon ablation, recovered intraprocedurally
1
No major complications

Original publication

Transseptal puncture for catheter ablation of atrial fibrillation in patients with septal occluder devices. Heart Rhythm. Published 3 April 2025. doi:10.1016/j.hrthm.2025.03.1996