Arrhythmias & electrophysiology

Utility of Very High-Output Pacing to Identify Ventricular Tachycardia (VT) Circuits in Patients Manifesting Traditionally Inexcitable Scar

JACC Clin ElectrophysiolPublished Retrospective cohort study

Authors' conclusion

In VT patients with a dense scar that is traditionally inexcitable, V-HOP can identify CCs of the re-entrant circuit and guide successful ablation.

Study context

Population
Patients undergoing VT ablation with dense myocardial scar requiring very high-output pacing (V-HOP) to capture sites of interest26 VT ablations
Participants
25 patients
Outcome
Identification of critical components (CCs) of VT circuits with V-HOP

Main finding

As reported in the abstract

VT successfully entrained with V-HOP (patients)
17
Central isthmus sites identified (patients)
10
Entrance/exit sites identified (patients)
4
VT terminated with RF ablation at these sites (patients)
15
Scar locations with delayed exit identified (patients)
9
Acute procedural success (patients)
24

Observational data: associations, not effects.

Further findings

OutcomeValues
VT recurrence requiring repeat ablation · follow-up 16 ± 21 monthsV-HOP 2 events
VT recurrence requiring repeat ablation — Same location targeted successfully at repeat ablation (patients)
1

Safety

No adverse events

Original publication