Coronary disease & ACS

Value of cardiovascular magnetic resonance–derived quantitative myocardial blood flow assessment in the setting of chronic coronary occlusion

Eur Heart J Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

Addition of fully automated MBF quantification to clinical routine visual S-CMR reading facilitates non-invasive differentiation between CTO and severe stenosis and provides higher sensitivity regarding true ischaemic burden in patients with CTO and multi-vessel disease

Study context

Population
Consecutive patients undergoing stress perfusion CMR and coronary angiography, February 2023–November 2024
Participants
130 patients
Comparison
Fully automated quantitative myocardial blood flow (MBF) assessment by stress perfusion CMR in chronic total occlusion (CTO) vs severe stenosis vs non-obstructed coronary arteries
  • Non-obstructedn = 57reference
  • Severe stenosisn = 37
  • CTOn = 36
Outcome
Diagnostic performance of CMR-derived fully automated quantitative MBF assessment in CTO
Methodological detailsconsecutive patients, single-centre
  • Consecutive patients
  • Single-centre

Performance

As reported in the abstract

Segmental stress MBF <1.02 mL/g/min to differentiate CTO from severe stenosis
Test or modelAUC (vs severe stenosis)
CTO0.792 (95% CI 0.678-0.887)

CTO

AUC (vs severe stenosis)0.792 (95% CI 0.678-0.887)

Further findings

OutcomeCTO
Detection of additional severe stenosis in CTO patients by integrated visual and quantitative perfusion assessment
Sensitivity91.3%

Original publication

Value of cardiovascular magnetic resonance–derived quantitative myocardial blood flow assessment in the setting of chronic coronary occlusion. Eur Heart J Cardiovasc Imaging. Published 8 September 2025. doi:10.1093/ehjci/jeaf263

Composed by AI from the published abstract and checked against it. How Briefs are made →