Valvular & structural heart diseaseCohort study

1-Year Outcomes of Transcatheter Aortic Valve Replacement Using a Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve

JACC Cardiovasc IntervPublished

  • Retrospective cohort study
  • propensity-score matched
  • 3 centres

Authors' conclusion

Despite differing immediate results, the outcomes at 1 year, including the composite of all-cause mortality, stroke, or hospitalization, were similar for neo2 and Ultra transcatheter heart valves.

Study context

Population
Patients undergoing transfemoral TAVR
Participants
2,106 patients · 702 matched pairs
Exposure
Self-expanding ACURATE neo2 vs balloon-expandable SAPIEN 3 Ultra
  • neo2n = 1,166
  • Ultran = 940reference
Outcome
Composite of:
  • All-cause mortality
  • Stroke
  • Rehospitalization
Follow-up
1 year

Main finding

As reported in the abstract

P = 0.819

Observational data: associations, not effects.

Secondary outcomes

Device success · irrespective of matching

P = 0.007

Mean pressure gradient after the procedure

P < 0.001

Individual components of the primary endpoint · 1 year

No difference between the groups

Safety

In-hospital complications

Paravalvular leakage, device embolization and multiple valve implantations more common with neo2
Major cardiac structural and major vascular complications more frequent with Ultra
All other in-hospital complication rates similar

Original publication

1-Year Outcomes of Transcatheter Aortic Valve Replacement Using a Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve. JACC Cardiovasc Interv. Published 20 November 2024. doi:10.1016/j.jcin.2024.09.042

Summarised from the published abstract; every number is checked against it