Arrhythmias & electrophysiology

A tailored approach to cardioneuroablation for reflex syncope and functional bradycardia: results from the ELEGANCE multicentre study

EuropacePublished Prospective cohort study

Authors' conclusion

An individualized CNA strategy, simplified by targeting specific GPs according to patient's pathophysiology, achieved outcomes equivalent to the standard approach while improving procedural efficiency through reduced RF delivery, shorter procedure duration, and limited ablation extent.

Study context

Population
Patients with reflex syncope and functional bradycardia undergoing cardioneuroablation73 men
Participants
123 patients
Exposure
Tailored vs standard cardioneuroablation
  • Tailoredn = 54
  • Standardn = 69reference
Outcome
Procedural data
Methodological detailsmulticentre, European
  • Multicentre
  • European

Main finding

As reported in the abstract

Acute procedural success

P = 0.98

OutcomeTailoredStandardP value
Procedure time63 min85 minP = 0.005
RF time5.4 min10.4 minP < 0.001
Heart rate increase40 ± 30.7%40 ± 31.4%P = 0.96
GPs targeted per patient1.6 ± 0.7Not reported in the abstractStandard: not reported in the abstract

Observational data: associations, not effects.

Further findings

Syncope recurrence · median 15.9 months [IQR: 9.8, 24.6] follow-up

No differences in syncope recurrence rate
log-rank P = 0.96

Safety

Inappropriate sinus tachycardia

P = 0.79

Inappropriate sinus tachycardia — Overall
8.1%

Original publication

A tailored approach to cardioneuroablation for reflex syncope and functional bradycardia: results from the ELEGANCE multicentre study. Europace. Published 30 December 2025. doi:10.1093/europace/euaf320

Summarised from the published abstract; every number is checked against it