Valvular & structural heart disease

Aging of the tricuspid valve annulus detected by photon-counting detector computed tomography: Importance of aortic root compression on occurrence of arrhythmias

Heart RhythmPublished consecutive patients who underwent photon-counting detector computed tomography

Authors' conclusion

Aortic root compression deforms the TVA and alters the anatomic relationship between the atrioventricular conduction system and the cavotricuspid isthmus. Therefore, aortic root compression may contribute to the occurrence of atrial tachyarrhythmias and conduction disturbances in older patients.

Study context

Population
Consecutive patients who underwent photon-counting detector computed tomography, excluding those with diseases that directly influenced the right side of the heartconsecutive patients analyzed
Participants
147 patients
Comparison
Patients with severe tricuspid valve annulus (TVA) compression vs without severe compression; older vs younger patients
Outcome
TVA deformation by aortic root compression
Methodological detailssingle institute, 3-dimensional endoscopic view of the heart
  • Single institute
  • 3-dimensional endoscopic view of the heart

Main finding

As reported in the abstract

  • Aortic root compression caused significant TVA deformation

Further findings

Atrial tachyarrhythmias · more frequent with severe compression

P < 0.01

Atrioventricular conduction disturbances · more frequent with severe compression

P < 0.01

Prevalence of severe TVA compression in elderly patients (age ≥75 years)

Severe compression in age ≥75 years
44%
  • P < .01

Distance between membranous septum and ostium of coronary sinus; cavotricuspid isthmus length

Membranous septum–coronary sinus ostium distance shortened and cavotricuspid isthmus elongated in older patients

Contributors to TVA compression (regression analysis)

Aging a significant contributor to TVA compression

TVA axes

Short minor and long major axes of the TVA more frequent with severe compression

Original publication

Aging of the tricuspid valve annulus detected by photon-counting detector computed tomography: Importance of aortic root compression on occurrence of arrhythmias. Heart Rhythm. Published 5 April 2025. doi:10.1016/j.hrthm.2025.03.2002

Composed by AI from the published abstract and checked against it. How Briefs are made →