Heart failure & cardiomyopathies

Association between echocardiography-derived haemodynamic force parameters and left ventricular reverse remodelling after cardiac resynchronization therapy

Eur Heart J Cardiovasc ImagingPublished Observational cohort study

Authors' conclusion

The orientation of HDF at baseline is associated with LV response to CRT. Six months after CRT, the orientation of HDF improves in LV responders and LV non-responders, while the magnitude of AB HDF only improves in LV responders.

Study context

Population
Patients with HF undergoing cardiac resynchronization therapy (CRT)136 (69%) left ventricular (LV) responders
Participants
196 patients
Exposure
LV responders vs LV non-responders to CRT
  • LV respondersn = 136
Outcome
LV response (reduction of LV end-systolic volume ≥ 15%) and its association with baseline echocardiography-derived haemodynamic forces
Follow-up
Six months

Main finding

As reported in the abstract

Baseline HDF associated with LV response (multivariable logistic regression)
Separate model
Odds ratio (95% CI)P value
Force vector angle, complete heart cycle
1.083(1.018–1.153)
P = 0.012
Systolic force vector angle
1.089(1.021–1.161)
P = 0.009

Observational data: associations, not effects.

Further findings

Change in haemodynamic forces (HDF) 6 months after CRT · six months

LV responders: greater apical-basal (AB) strength, AB impulse and higher force vector angles
LV non-responders: improvement only in force vector angle in complete heart cycle

Original publication