Cardiac Power Output Ratio: Novel Survival Predictor After Percutaneous Ventricular Assist Device in cardiogenic shock

ESC Heart FailPublished Registry-based cohort study

Authors' conclusion

In post-PVAD patients, the CPO ratio outperformed the absolute CPO values and other haemodynamic metrics in predicting survival at 90 days.

Study context

Population
Cardiogenic shock patients after percutaneous ventricular assist device (PVAD), QEH-PVAD RegistryCardiac power output (CPO) ratio available in 68
Participants
121 patients
Exposure
CPO ratio vs 24-h CPO vs early CPO as predictors of 90-day survival
Outcome
Survival
Follow-up
90 days after PVAD
Methodological detailsconsecutive patients, 98 of 121 underwent right heart catheterization after PVAD
  • Consecutive patients
  • 98 of 121 underwent right heart catheterization after PVAD

Main finding

As reported in the abstract

Prediction of 90-day survival · 90 days
GroupAUC
CPO ratio0.816
24-h CPO0.740
Early CPO0.469

AUC

CPO ratio0.816
24-h CPO0.740
Early CPO0.469

Observational data: associations, not effects.

Further findings

Correlates of CPO ratio

Not associated with age, sex or body size
Lower CPO ratio: significantly lower coronary perfusion pressure, worse right heart indices, higher pulmonary vascular resistance
Lower CPO ratio significantly associated with mechanical ventilation and higher creatine kinase in MI patients

Original publication