Valvular & structural heart disease

Effect of Transcatheter Aortic Valve Replacement Program Ratings on Case Selection

JACC Cardiovasc IntervPublished Retrospective cohort study

Main finding · Elixhauser comorbidity scoreResult — go to the resultDifference-in-difference estimator −0.48 95% CI −0.66 to −0.31

Authors' conclusion

Since 2020, there has been a substantial decline in the number of high-risk patients receiving TAVR across the United States, driven predominantly by hospitals that received lower USNWR TAVR ratings.

Study context

Population
Medicare fee-for-service beneficiaries undergoing transcatheter aortic valve replacement (TAVR) at USNWR-rated US hospitals618 hospitals
Exposure
Lower rated hospitals vs High-performing hospitals
Outcome
Patient risk profile (Elixhauser comorbidity score)
Methodological detailsdifference-in-difference analysis
  • Difference-in-difference analysis

Main finding

Elixhauser comorbidity score · after ratings release

Difference-in-difference estimator

−0.48

95% CI −0.66 to −0.31

P < 0.0001

Lower rated vs High-performing
difference-in-difference estimator −0.48 (95% CI −0.66 to −0.31); P < 0.0001

As reported in the abstract

Observational data: associations, not effects.

Further findings

OutcomeIRR (95% CI)P value
Number of high-risk TAVR cases (Elixhauser score > 20) · after ratings release · all hospitals declined; greater decline at lower rated0.56 (0.51–0.62)P < 0.0001

Original publication

Effect of Transcatheter Aortic Valve Replacement Program Ratings on Case Selection. JACC Cardiovasc Interv. Published 24 November 2025. doi:10.1016/j.jcin.2025.09.022

Summarised from the published abstract; every number is checked against it