Electromechanical Window Negativity and Arrhythmic Risk in Arrhythmogenic Mitral Valve Prolapse

JACC Cardiovasc ImagingPublished retrospective

Authors' conclusion

EMW is markedly negative in patients with AMVP/VA, reflecting electromechanical discordance. Thus, EMW emerges as a promising risk-associated marker in (A)MVP.

Study context

Population
Healthy controls and patients with mitral valve prolapse with or without ventricular arrhythmiaderivation cohort plus validation cohort · derivation cohort: controls 31 · derivation cohort: Mitral valve prolapse (MVP)/-VA 31 · derivation cohort: AMVP/nsVA 29 · derivation cohort: AMVP/VA 14 · validation cohort (with [A]MVP) 76
Participants
31 / 31 / 29 / 14
Exposure
Electromechanical window (EMW) inMVP vs controls, and as a marker identifying AMVP/VA
  • controlsn = 31
  • MVP/-VAn = 31
  • AMVP/nsVAn = 29
  • AMVP/VAn = 14
Methodological details3 centers (derivation cohort), independent validation cohort from 2 centers, EMW calculated blinded
  • 3 centers (derivation cohort)
  • Independent validation cohort from 2 centers
  • EMW calculated blinded

Main finding

As reported in the abstract

QAoCc, QTc and EMW, (A)MVP vs controls

(A)MVP

−18

range in brackets −47 to −8 ms · ms

Borderline shorter QAoCc than controls
P = 0.06
Significantly longer QTc than controls
P < 0.0001
More negative EMW than controls
P < 0.0001

Observational data: associations, not effects.

Further findings

EMW in AMVP/VA
−71 · range in brackets −177 to −30 ms · ms

EMW in AMVP/VA

EMW was most negative in patients with AMVP/VA

Validation cohort

Findings reproduced in the validation cohort, albeit at different absolute values

EMW identifying AMVP/VA (pooled ROC analysis)

Area under the curve
0.82 (95% CI: 0.73-0.91)
Optimal cutoff EMW threshold
−30 ms
Sensitivity
0.71
Specificity
0.83
Significantly outperforming QTc and QAoCc

EMW and AMVP/VA status

EMW independently associated with AMVP/VA status and improved model performance in addition to established risk parameters

Original publication

Electromechanical Window Negativity and Arrhythmic Risk in Arrhythmogenic Mitral Valve Prolapse. JACC Cardiovasc Imaging. Published 16 October 2026. doi:10.1016/j.jcmg.2026.08.017

Summarised from the published abstract; every number is checked against it