Arrhythmias & electrophysiology
Feasibility and safety of leadless pacemaker implantation via the right internal jugular vein: primary results of the VAMPIRE multicenter prospective study.
Authors' conclusion
In this prospective multicenter registry of a first-line RIJV approach for LP implantation, feasibility and procedural success were high, and 30-day major complications rate low. These results support the RIJV route as a safe and broadly applicable access strategy for LP implantation. However, dedicated studies are needed to compare safety versus the femoral approach.
Study context
- Population
- Consecutive patients with a guideline-directed LP indication undergoing a first-line right internal jugular vein (RIJV) approach for LP implantation, France (May 2024-May 2026)underwent a first-line RIJV approach, of 294 screened patients
- Participants
- 272 patients
- Outcome
- Major procedure- or system-related complications
- Follow-up
- Within 30 days
Methodological detailsconsecutive patients, 15 tertiary centres in France
- Consecutive patients
- 15 tertiary centres in France
Main finding
As reported in the abstract
Major procedure- or system-related complications
Major complications
6 of 272 patients
2.2%; 95% CI 0.8–4.7%p<0.001
Further findings
Successful LP implantation
- Successful LP implantation
- 266 of 272 patients (97.8%; 95% CI 95.3-99.2%)
- Septal deployment
- 94.3%
Procedure and fluoroscopy time
- Median procedure time
- 30 [25-40] minutes
- Median fluoroscopy time
- 2.5 [1.1-7.0] minutes
Baseline characteristics
- Median age
- 79 [73-85] years
- Male
- 63.6%
- Atrial fibrillation
- 51.5%
- Chronic kidney disease
- 34.9%
- Cancer
- 22.4%
- High-degree atrioventricular block as primary indication
- 84.9%
- Procedures performed urgently
- 65.8%
Original publication
Feasibility and safety of leadless pacemaker implantation via the right internal jugular vein: primary results of the VAMPIRE multicenter prospective study. Heart Rhythm. Published 17 November 2026. doi:10. 1016/ j. hrthm. 2026. 11. 014
Composed by AI from the published abstract and checked against it. How Briefs are made →