Imaging-based method to quantify left ventricular diastolic pressures
An erratum to this article was published (Eur Heart J Cardiovasc Imaging, 30 Sep 2025 ↗)
Authors' conclusion
The proposed non-invasive method provided estimates of minimum PLV, pre-A PLV, and end-diastolic PLV, each reflecting different features of diastolic function. Additionally, it provided an estimate of the LV diastolic pressure curve. Validation in larger populations with different phenotypes is necessary to determine the validity of the method in clinical practice.
Study context
- Population
- Patients suspected of coronary artery diseasepatients with LV pressure measured by micromanometers and images by echocardiography · 81 (derivative cohort) · 19 (testing cohort)
- Participants
- 115 patients
- Exposure
- Estimated vs measured LV diastolic pressures
- Outcome
- Agreement between estimated and measured pre-A PLV
Methodological detailsderivative cohort, testing cohort
- Derivative cohort
- Testing cohort
Main finding
As reported in the abstract
Bias
0.0
Limits of agreement (±1.96 SD)
< 3.1 mmHg
Key notes
- Testing cohort
Observational data: associations, not effects.
Further findings
Agreement of estimated minimum PLV and end-diastolic PLV with measured pressures
- Good agreement with measured pressures
Agreement between measured and estimated LV diastolic pressure curves (mean LV diastolic pressure)
- Bias
- 0.2
- Limits of agreement
- < 3.2 mmHg
Original publication