Heart failure & cardiomyopathies

Imaging modality for left ventricular ejection fraction estimation and effect of implantable cardioverter-defibrillator on mortality in patients with heart failure

Heart RhythmPublished Secondary analysis of the SCD-HeFT randomised trial

Authors' conclusion

We found no evidence that in patients with HF and LVEF ≤35%, the effect of ICD on mortality varied by the noninvasive imaging method used to measure LVEF.

Study context

Population
Patients with heart failure (HF) and left ventricular ejection fraction (LVEF) ≤35% in SCD-HeFT with LVEF measured by 2DE or MUGA2DE n = 971
Participants
1,386 patients
Comparison
ICD vs placebo, by LVEF imaging modality
  • ICDn = 692
  • Placebon = 694reference
Primary endpoint
All-cause mortality, by imaging subgroup (2DE vs MUGA)
Methodological detailssubgroup analysis
  • Subgroup analysis

Primary result

As reported in the abstract

All-cause mortality by imaging subgroup
ICD vs PlaceboHazard ratio (97.5% CI)
2DE subgroup
0.79(0.60–1.04)
MUGA subgroup
0.72(0.46–1.11)

Further findings

OutcomeICDPlaceboHR (97.5% CI)
All-cause mortality, overall23.1%29.7%0.77 (0.61–0.97)

Cardiac and arrhythmic mortality

Similar associations observed

Original publication

Imaging modality for left ventricular ejection fraction estimation and effect of implantable cardioverter-defibrillator on mortality in patients with heart failure. Heart Rhythm. Published 11 March 2023. doi:10.1016/j.hrthm.2023.03.010

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.