Authors' conclusion

ICE-detected wall thinning may be a novel imaging technique to identify arrhythmogenic periaortic VT substrate in this challenging anatomic region, which often eludes diagnosis with CMR. The absence of LGE on CMR does not rule out the presence of periaortic substrate in patients presenting with outflow tract VT.

Study context

Population
Ventricular tachycardia (VT) ablation patients with structural heart disease, categorized periaortic arrhythmogenic substrate (PAS)+ or PAS- by voltage-defined scar and deceleration zonesPAS+ 29, PAS- 55
Participants
84 patients
Comparison
Intracardiac echocardiography (ICE) wall thickness vs CMR-LGE for detecting periaortic arrhythmogenic substrate
Outcome
Diagnostic performance for PAS+ (sensitivity, specificity, PPV, NPV)
Methodological detailsindependent core lab
  • Independent core lab

Performance

As reported in the abstract

Detection of PAS+
Test or modelSensitivitySpecificityPPVNPV
ICE58%87%71%80%
CMR-LGE50%84%69%70%

Sensitivity

ICE58%
CMR-LGE50%

Specificity

ICE87%
CMR-LGE84%

PPV

ICE71%
CMR-LGE69%

NPV

ICE80%
CMR-LGE70%

Further findings

ICE wall thickness at 1 cm from LV ostium

P < 0.001

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Intracardiac Echocardiography for the Detection of Arrhythmogenic Periaortic Ventricular Tachycardia Substrate: Multimodality Core Lab Analysis. JACC Clin Electrophysiol. Published 17 September 2025. doi:10.1016/j.jacep.2025.06.012

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.