Arrhythmias & electrophysiology

Myocardial Damage, Inflammation, Coagulation, and Platelet Activity During Catheter Ablation Using Radiofrequency and Pulsed-Field Energy

JACC Clin ElectrophysiolPublished Randomised controlled trial

Authors' conclusion

Despite 10 times more myocardial damage, pulsed-field ablation was associated with a similar degree of platelet/coagulation activation, and slightly lower inflammatory response.

Study context

Population
Patients with AF indicated for pulmonary vein isolation (PVI)
Participants
65 patients
Comparison
Pulsed-field ablation (PFA) vs radiofrequency (RF) ablation for PVI
  • PFAn = 33
  • RFn = 32reference
Primary endpoint
Systemic response: markers of myocardial damage (troponin I), inflammation (interleukin-6), coagulation (D-dimers, fibrin monomers, von Willebrand antigen and factor activity) and platelet activation (P-selectin, activated GpIIb/IIIa antigen)
Follow-up
Before procedure, after trans-septal puncture, after LA ablation, and 1 day after

Primary result

As reported in the abstract

Peak troponin release

Further findings

OutcomePFARFP value
Procedural time55:09 ± 11:57 min151:19 ± 41:25 minP < 0.001
Left atrial dwelling time36:00 ± 8:05 min115:58 ± 36:49 minP < 0.001

Original publication

Myocardial Damage, Inflammation, Coagulation, and Platelet Activity During Catheter Ablation Using Radiofrequency and Pulsed-Field Energy. JACC Clin Electrophysiol. Published 6 November 2023. doi:10.1016/j.jacep.2023.11.001

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.