Novel Contrast-Derived Indices of Coronary Microvascular Function: Potential Clinical and Cost Benefits

Circ Cardiovasc IntervPublished diagnostic accuracy study of contrast-derived indices of coronary microvascular function

Authors' conclusion

Contrast-derived indices have high specificity and negative predictive value, enabling rapid exclusion of microvascular dysfunction. This method is feasible, clinically useful and cost-saving compared with routine adenosine testing.

Study context

Population
Patients undergoing coronary microvascular function testing with a diagnostic guidewire (median age 63 years; 62% women; 13% with diabetes)patients, 106 coronary arteries · coronary arteries 106 · patients 93
Participants
93 patients
Comparison
Contrast-derived indices vs abnormal adenosine-derived indices
Outcome
Contrast-derived coronary flow reserve <2.0 for predicting adenosine-derived coronary flow reserve

Performance

As reported in the abstract

Test or modelArea under the curveSensitivitySpecificityPositive predictive valueNegative predictive value
Contrast-derived coronary flow reserve <2.00.8167%80%40%92%

Contrast-derived coronary flow reserve <2.0

Area under the curve0.81
Sensitivity67%
Specificity80%
Positive predictive value40%
Negative predictive value92%

Further findings

OutcomeValues
Contrast-derived index of microcirculatory resistance >47 for predicting adenosine-derived indexcontrast-derived index of microcirculatory resistance >47 area under the curve 0.82 · sensitivity 80% · specificity 79% · positive predictive value 60% · negative predictive value 91%
Contrast-derived microvascular resistance reserve <1.9 for predicting adenosine-derived microvascular resistance reservecontrast-derived microvascular resistance reserve <1.9 area under the curve 0.82 · sensitivity 67% · specificity 89% · positive predictive value 35% · negative predictive value 97%

Assessments in left anterior descending artery

Assessments undertaken in the left anterior descending artery
88%

Fractional flow reserve

Median fractional flow reserve (interquartile range, 0.85-0.92)
0.88

Repeatability from the second contrast bolus

Good correlation on repeatability testing

Hybrid approach: adenosine use and cost

Reduction in adenosine use
40%
Saving per 1000 vessels assessed (USA)
$30 800
Saving per 1000 vessels assessed (UK)
£8000

Original publication

Novel Contrast-Derived Indices of Coronary Microvascular Function: Potential Clinical and Cost Benefits. Circ Cardiovasc Interv. Published 1 May 2025. doi:10.1161/circinterventions.124.015058

Summarised from the published abstract; every number is checked against it