Renal safety of high-dose pulsed field ablation of atrial fibrillation: A prospective real-world analysis

Heart RhythmPublished prospective real-world analysis

Authors' conclusion

The safety margin for the number of PFA applications seems to be higher in real-world practice; delivering 70-100 PFA applications via a pentaspline catheter during AF ablation remains a relatively low risk of AKI.

Study context

Population
Patients treated with pulsed field ablation (PFA) for atrial fibrillation (AF)consecutive patients treated with PFA for AF
Participants
115 patients
Exposure
Acute kidney injury (AKI) vs non-AKI groups; correlation of hemolysis and AKI with number of PFA applications
  • AKIn = 8
Outcome
AKI
Follow-up
24 hours after the procedure
Methodological detailsconsecutive patients
  • Consecutive patients

Main finding

As reported in the abstract

Patients who developed AKI

8 patients

7%

Clinically significant renal dysfunction

1 case

Observational data: associations, not effects.

Further findings

OutcomeAKInon-AKIP value
PFA applicationsNo statistical difference88.25 ± 35.3770.12 ± 16.94P = 0.5

Change in serum creatinine (SCr) across 4 subgroups based on PFA applications in quartiles · 24 hours after the procedure

Comparable across quartile subgroups
P = 0.1

Increase in SCr per pulse

Clinically relevant increase in SCr per pulse, only with more than 38 PFA applications
0.004 mg/dL
Pulses required to produce 0.3 mg/dL increase in SCr
≈140

Original publication

Renal safety of high-dose pulsed field ablation of atrial fibrillation: A prospective real-world analysis. Heart Rhythm. Published 22 July 2025. doi:10.1016/j.hrthm.2025.07.026

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.