Arrhythmias & electrophysiology

Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias.

Study context

Population
Patients with left ventricular ejection fraction (LVEF) 35%–49% undergoing permanent pacemaker implantation without an implantable cardioverter-defibrillator (ICD) indication
Participants
243 patients
Outcome
Sustained VT/VF
Follow-up
Median 27 months

Main finding

As reported in the abstract

Patients meeting primary end point of VT/VF

11

4.5%

Observational data: associations, not effects.

Further findings

VT/VF with multivessel coronary artery disease (CAD)

ValuesSubhazard ratio (95% CI)P value
Multivessel CADCompeting risks regressionMultivessel CAD 9.8% · Annualized risk 4.3% per year5.4 (1.5–20.1)P = 0.01

Original publication

Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation. Heart Rhythm. Published 13 March 2024. doi:10.1016/j.hrthm.2024.03.026