Arrhythmias & electrophysiology

Safety and feasibility of cardiac electrophysiology procedures in ambulatory surgery centers

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

The results from this large multicenter study suggest that ASCs represent a safe and effective setting to perform a variety of cardiac electrophysiology procedures including CA.

Study context

Population
Consecutive cardiac electrophysiology procedures with same-day discharge at 6 ambulatory surgery centers (ASCs), mainly during the coronavirus pandemic under the CMS Hospitals Without Walls program
Participants
4,037 procedures
Exposure
Cardiac implantable electronic device (CIED) implantation vs catheter ablation (CA) in ASCs; ASCs vs hospital outpatient departments
  • CIED implantationn = 1,453reference
  • CAn = 1,779
  • Transesophageal echocardiography/cardioversionn = 779
  • Electrophysiology studiesn = 26
Outcome
Safety and outcomes (adverse events)
Methodological detailsmulticentre, 6 ambulatory surgery centres, consecutive procedures, same-day discharge
  • Multicentre
  • 6 ambulatory surgery centres
  • Consecutive procedures
  • Same-day discharge

Main finding

As reported in the abstract

Adverse events

P = 0.93

Observational data: associations, not effects.

Further findings

OutcomeCIED implantationCAP value
Urgent/unplanned postprocedure hospitalizationCIED implantation vs CA0.48%0.45%P = 0.89
Adverse events, ASCs vs hospital outpatient departments · CIED: 0.76% vs 0.65%
P = 0.71
Adverse events, ASCs vs hospital outpatient departments · CA: 0.73% vs 0.80%
P = 0.79

Original publication

Safety and feasibility of cardiac electrophysiology procedures in ambulatory surgery centers. Heart Rhythm. Published 5 August 2024. doi:10.1016/j.hrthm.2024.07.123

Composed by AI from the published abstract and checked against it. How Briefs are made →