Arrhythmias & electrophysiology

Transesophageal 3-dimensional echocardiographic guidance for pacemaker lead placement improves lead position accuracy and reduces fluoroscopy

Heart RhythmPublished Case-control study

Authors' conclusion

For pacemaker and ICD lead placement, 3DE guidance substantially improves the accuracy of lead placement in the septum, with a shorter QRS duration, while reducing fluoroscopy exposure.

Study context

Population
Patients undergoing pacemaker or implantable cardioverter-defibrillator (ICD) lead placement
Participants
59 vs 72
Comparison
3DE-guided vs fluoroscopy-only pacemaker/ICD lead placement
  • 3DEn = 59
  • Historical controlsn = 72reference
Outcome
Ventricular lead placement in the septum
Methodological detailssingle-centre, historical controls
  • Single-centre
  • Historical controls

Main finding

As reported in the abstract

Ventricular lead location

Septum

P < 0.001

Free wall

P < 0.001

Observational data: associations, not effects.

Further findings

Ventricular lead location, pacemaker leads only (subgroup)

Septum

P < 0.001

Free wall

P < 0.001

Fluoroscopy time, all leads

P = 0.005

Fluoroscopy time, RV leads

P = 0.014

Paced QRS duration · trend

P = 0.084

Original publication

Transesophageal 3-dimensional echocardiographic guidance for pacemaker lead placement improves lead position accuracy and reduces fluoroscopy. Heart Rhythm. Published 6 December 2024. doi:10.1016/j.hrthm.2024.12.003

Composed by AI from the published abstract and checked against it. How Briefs are made →