Arrhythmias & electrophysiology

Genetics in Probands With Idiopathic Ventricular Fibrillation: A Multicenter Study

JACC Clin ElectrophysiolPublished Retrospective cohort study

Authors' conclusion

In probands with IVF, undergoing genetic analysis with a broad panel, the diagnostic yield for P+ is 6.7%. P+ or VUS carrier status is a predictor of VA occurrence.

Study context

Population
Probands with idiopathic VF undergoing broad gene panel analysisvariant in 12
Participants
45 probands
Exposure
P+ or variants of unknown significance (VUS) carriers vs no variants
  • VUSn = 9
  • P+n = 3
Outcome
Occurrence of ventricular arrhythmias (VA)
Follow-up
Mean 105.0 months
Methodological detailsmulticentre, consecutive probands
  • Multicentre
  • Consecutive probands

Main finding

As reported in the abstract

VA-free survival

VUS vs no variants (NO-V): P < 0.001 · P+ vs NO-V: P = 0.013

Ventricular arrhythmias (VA) in whole cohort
16 patients (35.6%)

Observational data: associations, not effects.

Further findings

Diagnostic yield for P+

Diagnostic yield for P+
6.7%

Deaths · mean follow-up 105.0 months

Deaths
0

Original publication

Genetics in Probands With Idiopathic Ventricular Fibrillation: A Multicenter Study. JACC Clin Electrophysiol. Published 24 May 2023. doi:10.1016/j.jacep.2023.03.008

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.