Arrhythmias & electrophysiology

Incidence and temporal evolution of delayed peridevice leak after left atrial appendage closure

Heart RhythmPublished Retrospective cohort study

Authors' conclusion

Despite design improvements, LAAC with Watchman FLX demonstrates a significant incidence of PDL with meaningful clinical implications. Regardless of initial size, most leaks regressed over time.

Study context

Population
Patients undergoing left atrial appendage closure (LAAC) with Watchman FLX with no peridevice leak (PDL) at implantationcompleted imaging
Participants
355 patients
Outcome
Incidence of new PDL at initial imaging
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

New PDL at initial imaging · 47 days (IQR 44-50 days)

New PDL

139

39%

Leak size, mean ± SD

3.2 ± 1.4 mm

Leak size, median (IQR; range)

3.0 mm

2.0–4.0 mm; 1.0–9.0 mm

Observational data: associations, not effects.

Secondary outcomes

Composite (continued OAC, device-related thrombus, stroke/TIA, major bleeding, need for PDL closure) · longest follow-up

P < 0.001

Predictors of PDL

Multiple deployment attempts and larger device size were positive predictors; increased contrast volume was a negative predictor

Temporal evolution of leak size (surveillance imaging, 43 [31%] of PDL patients) · 46 days to 189 days

Leak size at 46 days (IQR 44-51 days)
3.7 ± 1.8 mm
Leak size at 189 days (IQR 158-285 days)
1.7 ± 2.0 mm
Regressed
33 (77%)
Stable
4 (9%)
Progressed
6 (14%)
  • P < .001

Original publication

Incidence and temporal evolution of delayed peridevice leak after left atrial appendage closure. Heart Rhythm. Published 24 May 2024. doi:10.1016/j.hrthm.2024.05.035

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.