Arrhythmias & electrophysiology

Long-Term Outcomes of Brugada Substrate Ablation: A Report from BRAVO (Brugada Ablation of Ventricular Fibrillation (VF) Substrate Ongoing Multicenter Registry)

CirculationPublished Multicentre international registry study

Authors' conclusion

Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS.

Study context

Population
High-risk symptomatic Brugada syndrome with spontaneous VF, undergoing epicardial substrate ablation
Participants
159 participants
Outcome
Freedom from VF recurrence
Follow-up
Mean 48±29 months from last ablation

Main finding

As reported in the abstract

Free of VF after a single procedure

128 of 159

81%

Free of VF after repeated procedure (mean 1.2±0.5 procedures; median=1)

153

96%

Kaplan-Meier VF-free survival beyond 5 years after last ablation

95%

Observational data: associations, not effects.

Further findings

Predictor of VF-free outcome (multivariable): normalization of type 1 Brugada ECG after ablation

HR (95% CI)P value
Normalization of type 1 Brugada ECGWith and without sodium-channel blockade0.078 (0.008–0.753)P = 0.0274

VF burden and frequency of shocks

Before ablation
1.1±2.1 per month
After last ablation
0.003±0.14 per month
  • P<0.0001

Location of VF/Brugada syndrome (BrS) substrate

Epicardial RV outflow tract
all patients
Also inferior RV epicardium
45 (29%)
Posterior LV epicardium
3

Arrhythmic or cardiac deaths

Arrhythmic or cardiac deaths
0

Safety

Hemopericardium
4 (2.5%)

Original publication

Long-Term Outcomes of Brugada Substrate Ablation: A Report from BRAVO (Brugada Ablation of VF Substrate Ongoing Multicenter Registry). Circulation. Published 24 March 2023. doi:10.1161/circulationaha.122.063367

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.