Arrhythmias & electrophysiology

Predictor of A4 amplitude using preprocedural electrocardiography in patients with leadless pacemakers

Heart RhythmPublished Retrospective cohort study

Main finding · Independent predictor of high A4 amplitude (multivariate logistic analysis)Result — go to the resultOdds ratio 0.78 95% CI 0.67–0.92

Authors' conclusion

Preoperative electrocardiographic evaluations of P-wave morphology may be useful for predicting A4 amplitude. MDI was the only independent A4 amplitude predictor that seemed promising for selecting Micra-AV patients.

Study context

Population
Patients receiving Micra-AV VDD leadless pacemaker implantation, Tottori University Hospital, Nov 2021–Aug 2023 (median age 84 years; 64% male)
Participants
50 patients
Exposure
High-A4 vs low-A4
  • High-A4n = 26
  • Low-A4n = 24reference
Outcome
Preoperative predictors of A4 amplitude (ECG P-wave parameters: duration, amplitude, maximum deflection index [MDI], dispersion)
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Independent predictor of high A4 amplitude (multivariate logistic analysis)

Odds ratio

0.78

95% CI 0.67–0.92

P = 0.003

High-A4vs low-A4 (median split of A4 amplitude)
OR 0.78 (95% CI 0.67–0.92); P = 0.003

Observational data: associations, not effects.

Further findings

Between-group differences (high-A4 vs low-A4)

LVEF significantly different
P = 0.01
P-wave dispersion significantly different
P = 0.01
Maximum deflection index (MDI) significantly different
P < 0.001

Original publication

Predictor of A4 amplitude using preprocedural electrocardiography in patients with leadless pacemakers. Heart Rhythm. Published 19 February 2024. doi:10.1016/j.hrthm.2024.02.033

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.